S+S+
S+
10.1.8 Omitting one or more zones
If one or more immediate zones are triggered whilst in exit mode a low pitched error tone
will be produced. If this occurs return the panel to DAY mode by entering either the
Master code or Limited User code. If the log is then viewed any faulty zones will be
displayed as above. First check for any obvious reason for these zones to have been
activated. This may simply be due to a monitored door or window being left open or a pet
being left in a protected area. If the fault cannot be rectified it is possible to omit faulty
zones but this should only be used as a last resort if the building is to be left unoccupied.
Example:
Set panel (error tone will be heard).
Unset panel (alarm LED will be flashing).
View log to see which zones are faulty
and investigate fault(s) if possible.
Set panel,
then: If no error tone heard, exit via normal route.
or: If error tone heard:
Enter:
then; number(s) of zones to be omitted (1 to 6)
then: - Entry / Exit timer will start again.
then: exit building by normal route.
10.2 MASTER USER FACILITIES
The Master has access to all the Limited User facilities as well as those listed below. The
Paragon Super control panel has to be in day mode after resetting with the Master code
for these additional features to be accessed.
10.2.1 Event Log Reset
Enter:
This feature will only operate if, whilst programming, the engineer
selected the feature allowing the Master User to clear event log.
10.2.2 Resetting alarm LED after an Activation
Turn system off / back to Day Mode
Enter: Master User Code
or Limited User Code
Alarm LED will be flashing View log
Enter Last event will appear on the 7 segment display
Scroll through events:
Backwards
Forwards
To clear 7 segment display
Enter
8.5 LOW VOLTAGE CONNECTIONS
Extension loudspeakers (SPK)
Minimum 8 Ohms load or 2 x 16 Ohms in parallel.
SPK- (B - terminal) : 0 volts
SPK+ (SPK terminal) : speaker supply
Strobe Lamp STB (-terminal) : negative trigger
External Sounder/Bell
BA : negative trigger
S+ : 12 volts dc supply
B- : 0 volts
BT : Bell Tamper (Negative return)
Wiring for External Sounder: PANEL SOUNDER
Wiring for mechanical bell:
(non self actuating) PANEL BELL
Remote keypads
AUX- : 0V supply
KD : data transmit/receive
AUX+ : 12 volts dc supply
KT : keypad tamper