RDOC279 issue 1
C. ENGINEER FACILITIES
The engineer mode can only be accessed when the panel is in day mode.
10.3.1 Entering Engineer Mode
Enter
then Engineer code (Factory set 9999)
The fault light will flash for as long as the panel is in Engineer mode.
10.3.2 Leaving Engineer Mode
Enter
then Engineer code (Factory set 9999)
This will return the panel to day mode and the fault light will stop flashing.
10.3.3 Master User Facilities
The engineer has access to all the Master facilities but must prefix the function numbers
by
Key sequences are as follows:
Chime on/off View event log
Clear event log Change Limited User code
Change Master User code Enter System Test Mode
Enter Walk Test Mode
1 1 LED FUNCTION
Panel light on : Indicates there is mains on the system
RKP supply light on : Indicates DC supply to RKP
Day light on : Indicates the system is off. (Day mode)
Fault light on : Blown Auxiliary fuse
or Blown Bell fuse
or Mains Supply disconnected
Alarm light flashing : Indicates an Alarm activation
Tamper light flashing : Indicates a Tamper alarm
P.A light flashing : Indicates a Personal Attack activation
Fire light flashing : Indicates a Fire alarm activation
Fault light flashing : Engineer mode
Chime light on : Chime is on - Entry/Exit circuits
of last set-mode used