Pyronix Paragon Super Spezifikationen Seite 5

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 14
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 4
24
2. Check 250mA fuse on mains input
terminal block. (Below transformer)
10. Panel Waiting for Further Commands.
5
RDOC 279 issue 1
Day LED will flash if you have started a function but not f
inished the sequence. e.g
a. Enter (View Log)
Panel awaiting to terminate function.
b. (Change Limited User code) Awaiting codes.
c. (Change Master User code) Awaiting codes.
d. (Customer Test Procedure)
Use N
o
keys to scroll, to terminate.
11. Walk Test Mode.
Enter Chime Light will flash
Set Panel to desired set mode (Full, 1, 2 or 3)
Walk Test circuits.
Enter (Master Code) to exit.
12. Chime Mode.
Enter Chime Light will stay on.
The Paragon Super will remember its last Set Mode
i.e (Full, 1, 2 or 3).
Any zone programmed as Entry / Exit will chime
on going open circuit.
Enter to terminate feature.
LED will clear.
3 ACCESS LEVELS
3.1 Limited User level enables: a. Panel setting and unsetting with a
unique pass code.
b. Setting and unsetting of the door chime
facility.
c. Event log viewing.
3.2 Master User level enables: a. All Limited User facilities.
b. Alteration of both Limited and Master
User codes.
c. Walk test facility for all four set modes.
d. Clearing of event log (if allowed by the
Engineer).
e. LED / Strobe / Bell / Extension Speaker
test facility.
3.3 Engineer level enables: a. All Master User facilities except setting
and unsetting
b. Zone programming for all four set modes
c. Bell timer setting
d. Entry / Exit timer setting
e. Alteration of Engineer code
f. Enabling or Disabling of Event log reset by
Master user
4 FEATURES
- 3 Access-Level Codes, all programmable
- Easy-set facility
- 6 Programmable alarm zones
- 4 Set / Part Set modes
- Fire alarm zone with unique alarm sound
- Personal Attack alarm zone
- Tamper zone
- Dedicated Personal Attack key on keypad
- Dedicated Fire alarm key on keypad
- 18 Event Memory Log with forward and backward scroll
- Selectable Master User or Engineer Log reset
- Independent Walk Test facilities for each Set / Part set mode
- System Test Function
- Output for extension speaker with volume control and software override
- Optional remote keypads with internal sounders and volume control
- Programmable from any remote keypad
- Separate Bell and Strobe lamp outputs
- Zone omit facility on exit
- 16 key backlit keypad on the RKP
Seitenansicht 4