17
RDOC 279 issue 2
12
AUX-
AUX+
AUX+
AUX-
AUX-
AUX+
Wiring a single remote keypad. This requires 4 core cables.
Wiring for multiple remote keypads (daisy chain). This requires 4 core cable.
PANEL RKP
Wiring for multiple remote keypads (star configuration). This requires 5 core cable.
PANEL RKP1 RKP2
Alarm, P.A and Fire Zones
Wiring for normally closed contacts.
Wiring for normally open contacts.
Enter Volume will be determined by volume pot. i.e Reduced volume
10.1.3 Unsetting the panel
The panel can be unset by entering the building via the entry exit route and then keying
either of the two user codes.
10.1.4 Activating the Personal Attack Alarm (PA)
To activate the Personal Attack Alarm enter
10.1.5 Activating the Fire Alarm
To activate the Fire Alarm enter
10.1.6 Turning Chime On and Off (Panel must be in day mode)
Enter
The status of the chime facility is indicated by the chime LED on the front of the control
panel. When the chime mode is selected a two tone chime will be produced
by the internal sounder and any extension speakers when an Entry / Exit zone is
activated. The same key sequence can be used to turn off the chime facility.
10.1.7 Reading Event Log (Panel must be in day mode)
Enter
The day led will flash and the most recent event stored in the log will be displayed. If the
up arrow key is pressed the previous log entry will be displayed. Similarly if the down
arrow key is pressed the next most recent entry will be displayed.
The event log can be scrolled backwards and forwards using the up and down arrow
keys to allow the last 18 events to be viewed.
To leave this function press the key. An error tone will be produced if an attempt
is made to scroll outside either end of the event memory. The table below shows the
symbols stored in the event log and their meanings.
Entry/Exit zone activation.The panel was not unset before
the end of the entry time period, or User did not leave in time.
to Activation of a programmable zone.
This shows the next event in the log has triggered the alarm
system.
This shows that a zone was omitted and refers to the
number which precedes it in the log.
Tamper fault or sabotage.
Personal attack activation.
Fire alarm activation.
Panel
RKP 1
Panel
RKP 1
RKP 2
Panel
RKP 1
RKP 2